Dɛn ne ɔhyew a wɔde sesa nneɛma?

Sep 30, 2025 Gyae nkrasɛm bi .

Water  water Heat Exchanger Unit

Ɔhyew a wɔde sesa nneɛma, a wɔtaa frɛ no ɔhyew sesa gyinabea anaa HVAC mfiri, yɛ afiri a edi mũ, a wɔaka abom a ɛde ɔhyew fi ɔhyew fibea titiriw-afã a ɛto so abien-afã a ɛkyinkyini (te sɛ ɔhyew a wɔde yɛ atrae ne nsu a ɛyɛ hyew a wɔde yɛ adwuma wɔ fie) denam ɔhyew a wɔde sesa nneɛma so.

NoNneɛma a wɔde yɛ ɔhyew .yɛ ɔmantam mu ɔhyew sohwɛ mfiri a edi mũ a ɛka mprɛte mu ɔhyew sesa, pɔmpɛ a ɛma mogya no di akɔneaba, nsu a wɔde ma pɔmpɛ, thermometer, pressure gauge, sensor ahorow, pipe ne valve ahorow, ne mfiridwuma sohwɛ bom. Ɛsan nso wɔ nsuo a wɔde ma a ɛyɛ nhyɛsoɔ a ɛkɔ so daa, nsuo a wɔde yɛ adwuma, frequency flow control nhyehyɛeɛ a ɛsakra, calorimeter, ne network communication control system a ɛbɛdi control function configuration ahwehwɛdeɛ a ɛwɔ level ahodoɔ so no ho dwuma.

 

Ɔhyew sesa: Unit no koma, baabi a ɔhyew sesa. (Nea wɔtaa de di dwuma ne mprɛte a wɔde sesa ɔhyew, esiane sɛ ɛma ɔhyew no kɔ soro yiye ne sɛnea ɛyɛ ketewaa nti. Akorade ne tube ɔhyew sesa, ne nea ɛkeka ho nso wɔ hɔ.

Circulation Pump: Ɛma ahoɔden ma nsuo a ɛyɛ hyeɛ a ɛwɔ secondary side heating system no mu, sɛdeɛ ɛbɛyɛ a ɛbɛdi akɔneaba wɔ radiator ne heat exchange unit no ntam wɔ dan no mu.

heat exchanger

 

heat exchanger
Nneɛma a wɔde di dwuma: .

"Amemene" a ɛwɔ unit no mu, a mpɛn pii no ɛyɛ PLC (Programmable Logic Controller), ɔhyew sensor ahorow, nhyɛso sensor ahorow, anyinam ahoɔden sohwɛ valve, ne touchscreen onipa-afiri ntam nkitahodi. Ɛdenam nea ɛto so abien-afã a wɔde ma ne nsu a wɔsan de ma no hyew anaasɛ abɔnten hyew so no, ɛno ankasa sesa valve a ɛbue wɔ primary-afã ɔhyew fibea (steam anaa high-temperature nsu), a ɛnam so di secondary-afã outlet nsu hyew so pɛpɛɛpɛ, a ɛyɛ{6}}demand dwumadi ne ahoɔden a wɔde yɛ adwuma.

 

Electric Regulating Valve: Wɔde ahyɛ primary side heat source pipeline no mu, agye akwankyerɛ afi control system no hɔ, na ɛno ara bue anaasɛ ɛto mu de hwɛ ɔhyew a ɛkɔ ɔhyew sesa no mu no so.

Filter: Wɔde ahyɛ primary ne secondary side pipes no so de atwitwa efĩ a ɛwɔ nsuo no mu (te sɛ rust ne scale) na abɔ nnwinnadeɛ te sɛ ɔhyeɛ sesa ne nsuo pɔmpɛ ho ban afiri kwan a ɛbɛsi ne nea ɛbɛbɔ ho.

Instruments and valves: Nea ɛka ho ne pressure gauges, thermometers, safety valves, check valves, stop valves, ne nea ɛkeka ho Wɔde di dwuma de hwɛ nhyehyɛe no adwumayɛ parameters (nhyɛso, ɔhyew), hwɛ hu sɛ nhyehyɛe no yɛ adwuma wɔ ahobammɔ kwan so, na ɛma ɛyɛ mmerɛw sɛ wobesiesie na wɔasiesie.

Pipes and racks: Wɔde nneɛma no nyinaa ahyɛ nhyehyɛe a edi mũ mu na wɔde ahyɛ rack a ɛyɛ den so ma ayɛ mfiri a ɛyɛ mmerɛw na ɛyɛ fɛ.

 
 
Adwumayɛ Nnyinasosɛm:
3D diagram of heat exchanger unit

.

2. Ɔhyew a wɔde sesa: Ɔhyew a ɛkorɔn-ɔhyew a ɛwɔ ɔfã titiriw no sen fa .Ɔhyew a wɔde sesa nneɛma ., a ɛde ne hyew no kɔ fam-temperature secondary circulating nsu a ɛsen fa ɔfã foforo no (kyerɛ sɛ, nsu a ɛkɔ nea ɔde di dwuma no fie).

3. Ɔhyew sohwɛ: Control nhyehyɛe no de ɔhyew sensor di dwuma de hu nsu a ɛkɔ mu no hyew wɔ ɔfã a ɛto so abien no so. Sɛ ɔhyew no yɛ kɛse dodo a, ɛto primary side electric control valve no mu na ama ɔhyew a ɛkɔ no so atew; Sɛ ɔhyew no sua dodo a, ebue valve no ma ɔhyew no kɔ soro.

4. Nsuo a ɛyɛ hyeɛ a ɛkyinkyini: Nsuo a ɛtɔ so mmienu a ɛkyinkyini no nam pɔmpɛ a ɛkyinkyini so na ɛde fa nsuo afiri a ɛwɔ afiri no mu no mu kɔ radiator anaa fam a ɛyɛ hyeɛ afiri a ɛwɔ afie mpempem mu ma ɛma ɔhyeɛ no sɛe.

5. Ɔhyew a ɛba na ɛsan ba: Bere a wɔayi ɔhyew afi hɔ wɔ nea ɔde di dwuma no fie akyi no, .

Wɔde nsuo a ɛtɔ so mmienu a ɛsan de nsuo a ɛwɔ nsuo no mu no san kɔ ɔhyeɛ sesa afiri no mu denam nsuo a ɛkyinkyini no so na Re-ɛkɔ ɔhyew nsakraeɛ no mu ma ɛyɛ hyew. Saa kyinhyia yi san ba bio ma ɛyɛ loop a wɔato mu.

heat exchanger unit
 

Atenaeɛ a wɔde yɛ ɔhyew Ɔhyew a wɔde sesa nneɛma: Awɔw bere mu ɔhyew ma mmeae a wɔte, ɔfese adan, sukuu ahorow, ayaresabea ahorow, aguadidan akɛse, ne nea ɛkeka ho.

Nsu a ɛyɛ hyew wɔ fie: Nsu a ɛyɛ hyew a wɔde ma ahɔhodan, ahɔhodan, asuguarebea, ɔmanfo aguaree, ne nea ɛkeka ho.

Residential area heating units
School heating unit

Industrial field: ɔhyew ne onwini wɔ process flow mu, ne ɔhyew a ɛwɔ adwumayɛbea adan mu.

Ɔmantam no mu onwini: Wɔ awɔw bere mu no, ɛdenam nsu a ɛyɛ nwini a wɔde bɛka ho so no, wobetumi de nsu a ɛyɛ nwini a wɔde yɛ mframa ama adan.

Sɛ wopɛ sɛ wuhu pii fa heat exchanger units ho anaasɛ w’ani gye ho sɛ wobɛtɔ a, yɛsrɛ wo fa email kɔ 9988xiaoshuai@gmail.com, yɛbɛma wo mmuae wɔ bere mu bere a woahu nkra no akyi !